=====================  Product Identification  =====================

Product ID:AMMONIUM ACETATE, I-6
MSDS Date:12/01/1990
FSC:6810
NIIN:00N067651
MSDS Number: CBGGT
=== Responsible Party ===
Company Name:CHEM SERVICE INC
Box:3108
City:WEST CHESTER
State:PA
ZIP:19381
Country:US
Info Phone Num:215-692-3026
Emergency Phone Num:215-692-3026
CAGE:84898
=== Contractor Identification ===
Company Name:CHEM SERVICE INC
Box:3108
City:WEST CHESTER
State:PA
ZIP:19381
Country:US
Phone:215-692-3026
CAGE:84898
Company Name:CHEM SERVICE, INC
Address:660 TOWER LN
Box:599
City:WEST CHESTER
State:PA
ZIP:19301-9650
Country:US
Phone:610-692-3026
CAGE:8Y898

=============  Composition/Information on Ingredients  =============

Ingred Name:ACETIC ACID, AMMONIUM SALT; (AMMONIUM ACETATE) (CERCLA)
CAS:631-61-8
RTECS #:AF3675000
OSHA PEL:N/K 
ACGIH TLV:2 MG/M3 (MFR)
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:SUP DAT: IMMEDIATELY IF NECESSARY. GET MEDICAL ATTENTION IF
    NECESSARY. IF PATIENT IS VOMITING, WATCH CLOSELY TO (ING 3)
RTECS #:9999999ZZ

Ingred Name:ING 2: MAKE SURE AIRWAY DOES NOT BECOME OBSTRUCTED BY
    VOMIT.
RTECS #:9999999ZZ

Ingred Name:HYGIENE PRACT: CLOTHING UNTIL ABSOLUTELY FREE OF ALL
    CHEMICAL ODORS.
RTECS #:9999999ZZ

Ingred Name:OTHER PREC: USED AS DRUGS, COSMETICS, AGRICULTURAL OR
    PESTICIDAL PRODUCTS, FOOD ADDITIVES OR AS HOUSEHOLD CHEMICALS.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CAN CAUSE EYE IRRITATION. CAN
    CAUSE SKIN IRRITATION. MAY BE HARMFUL IF ABSORBED THROUGH THE SKIN.
    MAY BE HARMFUL IF INHALED. DUST AND/OR VAPORS CAN CAUSE IRRITATION
    TO RESPIRATORY TRACT. MAY BE  HARMFUL IF SWALLOWED. CAN BE
    IRRITATING TO MUCOUS MEMBRANES. CHRONIC: NONE SPECIFIED BY
    MANUFACTURER.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:AN ANTIDOTE IS A SUBSTANCE INTENDED TO COUNTERACT EFT OF
    POIS. IT SHOULD BE ADMIN ONLY BY MD/TRAINED EMER PERS. MED ADVICE
    CAN BE OBTAINED FROM POIS CTL CTR. EYES: FLUSH CONTINUOUSLY W/WATER
    FOR AT LE AST 15 MIN. SKIN: FLUSH W/WATER FOR 15-20 MIN. IF NO
    BURNS HAVE OCCURRED, USE SOAP & WATER TO CLEANSE SKIN. INHAL:
    REMOVE TO FRESH AIR. ADMIN OXYGEN IF DFCLT BRTHG. IF BRTHG HAS
    STOPPED, (SUP DAT)

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE CARBON DIOXIDE, DRY CHEMICAL POWDER OR SPRAY.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE AREA. WEAR APPROPRIATE OSHA REGULATED
    EQUIPMENT. VENTILATE AREA. SWEEP UP AND PLACE IN AN APPROPRIATE
    CONTAINER. HOLD FOR DISPOSAL. WASH CONTAMINATED SURFACES TO REMOVE
    ANY RESIDUES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:ALL CHEM SHOULD BE CONSIDERED HAZ.
    AVOID DIRECT PHYSICAL CONT! USE APPROP OSHA/MSHA APPRVD SFTY EQUIP.
    AVOID CONT W/SKIN, EYES & CLTHG.
Other Precautions:DO NOT BREATHE VAPS. KEEP TIGHTLY CLSD. STORE IN COOL
    DRY PLACE. STORE ONLY W/COMPATIBLE CHEMS. PERS NOT SPECIFICALLY &
    PROPERLY TRAINED SHOULD NOT HANDLE THIS CHEM/ITS CONTR. THIS PROD
    IS FURNISHED F OR LAB USE ONLY! PROD MAY NOT BE (ING 5)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
    FOR EXPOSURE OF CONCERN .
Ventilation:THIS CHEMICAL SHOULD BE HANDLED ONLY IN A HOOD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN IN THE
    LABORATORY. REMOVE AND WASH CONTAMINATED CLOTHING. DO NOT WEAR
    SHOES OR (ING 4)
Supplemental Safety and Health
FIRST AID PROC:ADMIN ARTF RESP. IF SIGNS OF SHOCK, KEEP WARM & QUIET.
    GET MED ATTN IF NEC. IF PATIENT IS IN CARD ARREST, ADMIN CPR.
    CONTINUE LIFE SUPPORTING MEASURES UNTIL MED ASSIST HAS ARRIVED.
    INGE ST:DO NOT ADMIN LIQS/INDUCE VOMIT TO UNCON/CONVL PERS. IF
    SWALLOWED DRINK 1-2 GLASSES OF WATER. CONT POIS CTL CTR(ING 2)

==================  Physical/Chemical Properties  ==================

Melt/Freeze Pt:M.P/F.P Text:237F,114C
Spec Gravity:1.07
Solubility in Water:SOLUBLE
Appearance and Odor:WHITE CRYSTALLINE SOLID

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
REACTS W/ACID HALIDES & ANHYDRIDES, PHOSPHORUS HALIDES, THIONYL
    CHLORIDE. CORRODES COPPER & ITS ALLOYS.
Stability Condition to Avoid:HYGROSCOPIC.
Hazardous Decomposition Products:DECOMP LIBERATES TOXIC FUMES. DECOMP
    UNDER ALKALINE CNDTNS. DECOMP PRODS ARE FLAMMABLE. DECOMP PRODS ARE
    CORROSIVE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:FLUSH TO SEWER WITH COPIOUS AMOUNTS OF WATER.
    DISPOSE OF IN ACCORDANCE W/LOCAL, STATE & FEDERAL REGULATIONS .

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.