DU PONT E I DE NEMOURS AND CO INC -- FREON TF 113 -- 6850-01-411-2475
=====================  Product Identification  =====================

Product ID:FREON TF 113
MSDS Date:11/23/1995
FSC:6850
NIIN:01-411-2475
MSDS Number: BZRCL
=== Responsible Party ===
Company Name:DU PONT E I DE NEMOURS AND CO INC
Address:DU PONT CHEMICALS FLUORCHEMICALS
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-7515/ 302-774-6822
Emergency Phone Num:800-441-3637/800-424-9300 (CHEMTREC
CAGE:2S827
=== Contractor Identification ===
Company Name:DU PONT FLUOROPRODUCTS
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:1-800-441-7515
CAGE:2S827

=============  Composition/Information on Ingredients  =============

Ingred Name:1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113) (SARA
    313)
CAS:76-13-1
RTECS #:KJ4000000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:1000PPM/1250STEL; 96
Ozone Depleting Chemical:1

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RAT) IS 43000 MG/KG
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION OR INGESTION MAY
    CAUSE CNS EFFECTS. INHALATION OF HIGH CONCENTRATIONS MAY CAUSE
    HEART IRREGULARITIES, ASPHYXIATION. INGESTION MAY CAUSE ASPIRATION
    WHICH CAUSE CHEMICAL PNEUMONITIS. S KIN OR EYE CONTACT MAY CAUSE
    IRRITATION. CHRONIC: NONE SPECIFIED BY MANUFACTURER.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
    OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:ASPIRATION-COUGHING, GASPING, CHOKING,
    SHORTNESS OF BREATH. INHALED/INGESTED-DIZZINESS, HEADACHE,
    CONFUSION, INCOORDINATION, LOSS OF COORDINATION, IRREGULAR
    PULSE/PALPITATIONS/INADEQUATE CIRCULATION.	SKIN-IRRITATION,
    TINGLING, NUMBNESS, COLDNESS, DRYING OF SKIN. EYES-IRRITATION,
    DISCOMFORT, TERAING, BLURRED VISION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:IN ALL CASES GET MEDICAL ATTENTION. EYES-IMMEDIATELY FLUSH
    WITH WATER FOR 15 MINUTES. SKIN-FLUSH WITH PLENTY OF WATER.
    INHALED-REMOVE TO FRESH AIR. ADMINISTER OXYGEN OR ARTIFICIAL
    RESPIRATION AS NEEDE D. INGESTED-DO NOT INDUCE VOMITING! CONSULT
    PHYSICIAN IF NEEDED.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Autoignition Temp:Autoignition Temp Text:572F
Extinguishing Media:UAW MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
    FULL FIRE FIGHTER'S PROTECTIVE GEAR. USE WATER TO COOL FIRE EXPOSED
    CONTAINERS.
Unusual Fire/Explosion Hazard:DRUMS MAY RUPTURE UNDER FIRE CONDITIONS.
    DECOMPOSITION MAY OCCUR.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA. DO NOT FLUSH TO SEWERS. DIKE
    SPILL. COLLECT ON ABSORBENT MATERIAL AND TRANSFER TO STEEL DRUMS
    FOR RECOVERY OR DISPOSAL. USE SCBA FOR LARGE SPILLS. COMPLY WITH
    LOCAL, STATE AND FEDERAL  REGULATIONS ON REPORTING RELEASES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY, CLEAN PLACE. DO
    NOT HEAT ABOVE 125F. USE WITH SUFFICIENT VENTILATION TO KEEP
    EXPOSURE BELOW RECOMMENDED LIMITS.
Other Precautions:AVOID BREATHING VAPORS AND PROLONGED SKIN EXPOSURE.
    NOTE TO PHYSICIANS: BECAUSE OF INCREASED CARDIAC ARRHYTHMIAS,
    CATECHOLAMINE DRUGS, SUCH AS EPINEPHRINE, SHOULD BE USED WITH
    SPECIAL CAUTION IN SITUA TIONS OF EMERGENCY LIFE SUPPORT.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE NORMALLY REQUIRED. IF ENGINEERING CONTROLS
    FAIL OR NON-ROUTINE USE OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH
    APPROVED AIR-SUPPLIED RESPIRATOR OR SCBA, AS REQUIRED. USE IAW 29
    CFR 1910.134.
Ventilation:USE ADEQUATE MECHANICAL VENTILATION OR LOCAL EXHAUST TO
    MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:IMPERVIOUS-NITRILE, BUTYL, PVA.
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
    DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
NOTE: "ANTIDOTE"-ACTIVATED CHARCOAL SLURRY MAY BE ADMINISTERED. TO
    PREPARE ACTIVATED CHARCOAL SLURRY SUSPEND 50 GRAMS ACTIVATED
    CHARCOAL ON 400 ML WATER IN PLASTIC BOTTLE AND SHAKE WELL.
    ADMINISTER 5  ML/KG OR 350 ML FOR AVERAGE ADULT. BECAUSE OF DANGER
    OF ASPIRATION, EMESIS OR GASTRIC LAVAGE SHOULD NOT BE EMPLOYED.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:118F,48C
Vapor Pres:334.1
Vapor Density:2.9
Spec Gravity:1.57
pH:NEUTRL
Evaporation Rate & Reference:>1 (CCL4=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR, COLORLESS LIQUID; SLIGHT ETHEREAL ODOR.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ALKALI AND ALKALINE EARTH METALS-POWDERED ALUMINUM, ZINC, BERYLLIUM,
    ETC.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:HYDROCHLORIC ACID, HYDROFLUORIC ACID
    AND POSSIBLY CARBONYL HALIDES.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
    FEDERAL ENVIRONMENTAL REGULATIONS. REMOVE TO A PERMITTED WASTE
    DISPOSAL FACILITY. EPA HAZARDOUS WASTE NUMBERS F001 AND F002 MAY
    APPLY TO WASTE MATERIALS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.