DU PONT E I DE NEMOURS AND CO INC -- FREON TF 113 -- 6850-01-411-2475
===================== Product Identification =====================
Product ID:FREON TF 113
MSDS Date:11/23/1995
FSC:6850
NIIN:01-411-2475
MSDS Number: BZRCL
=== Responsible Party ===
Company Name:DU PONT E I DE NEMOURS AND CO INC
Address:DU PONT CHEMICALS FLUORCHEMICALS
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-7515/ 302-774-6822
Emergency Phone Num:800-441-3637/800-424-9300 (CHEMTREC
CAGE:2S827
=== Contractor Identification ===
Company Name:DU PONT FLUOROPRODUCTS
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:1-800-441-7515
CAGE:2S827
============= Composition/Information on Ingredients =============
Ingred Name:1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113) (SARA
313)
CAS:76-13-1
RTECS #:KJ4000000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:1000PPM/1250STEL; 96
Ozone Depleting Chemical:1
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL LD50 (RAT) IS 43000 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION OR INGESTION MAY
CAUSE CNS EFFECTS. INHALATION OF HIGH CONCENTRATIONS MAY CAUSE
HEART IRREGULARITIES, ASPHYXIATION. INGESTION MAY CAUSE ASPIRATION
WHICH CAUSE CHEMICAL PNEUMONITIS. S KIN OR EYE CONTACT MAY CAUSE
IRRITATION. CHRONIC: NONE SPECIFIED BY MANUFACTURER.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:ASPIRATION-COUGHING, GASPING, CHOKING,
SHORTNESS OF BREATH. INHALED/INGESTED-DIZZINESS, HEADACHE,
CONFUSION, INCOORDINATION, LOSS OF COORDINATION, IRREGULAR
PULSE/PALPITATIONS/INADEQUATE CIRCULATION. SKIN-IRRITATION,
TINGLING, NUMBNESS, COLDNESS, DRYING OF SKIN. EYES-IRRITATION,
DISCOMFORT, TERAING, BLURRED VISION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:IN ALL CASES GET MEDICAL ATTENTION. EYES-IMMEDIATELY FLUSH
WITH WATER FOR 15 MINUTES. SKIN-FLUSH WITH PLENTY OF WATER.
INHALED-REMOVE TO FRESH AIR. ADMINISTER OXYGEN OR ARTIFICIAL
RESPIRATION AS NEEDE D. INGESTED-DO NOT INDUCE VOMITING! CONSULT
PHYSICIAN IF NEEDED.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Autoignition Temp:Autoignition Temp Text:572F
Extinguishing Media:UAW MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL FIRE FIGHTER'S PROTECTIVE GEAR. USE WATER TO COOL FIRE EXPOSED
CONTAINERS.
Unusual Fire/Explosion Hazard:DRUMS MAY RUPTURE UNDER FIRE CONDITIONS.
DECOMPOSITION MAY OCCUR.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA. DO NOT FLUSH TO SEWERS. DIKE
SPILL. COLLECT ON ABSORBENT MATERIAL AND TRANSFER TO STEEL DRUMS
FOR RECOVERY OR DISPOSAL. USE SCBA FOR LARGE SPILLS. COMPLY WITH
LOCAL, STATE AND FEDERAL REGULATIONS ON REPORTING RELEASES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL, DRY, CLEAN PLACE. DO
NOT HEAT ABOVE 125F. USE WITH SUFFICIENT VENTILATION TO KEEP
EXPOSURE BELOW RECOMMENDED LIMITS.
Other Precautions:AVOID BREATHING VAPORS AND PROLONGED SKIN EXPOSURE.
NOTE TO PHYSICIANS: BECAUSE OF INCREASED CARDIAC ARRHYTHMIAS,
CATECHOLAMINE DRUGS, SUCH AS EPINEPHRINE, SHOULD BE USED WITH
SPECIAL CAUTION IN SITUA TIONS OF EMERGENCY LIFE SUPPORT.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NORMALLY REQUIRED. IF ENGINEERING CONTROLS
FAIL OR NON-ROUTINE USE OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH
APPROVED AIR-SUPPLIED RESPIRATOR OR SCBA, AS REQUIRED. USE IAW 29
CFR 1910.134.
Ventilation:USE ADEQUATE MECHANICAL VENTILATION OR LOCAL EXHAUST TO
MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:IMPERVIOUS-NITRILE, BUTYL, PVA.
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
NOTE: "ANTIDOTE"-ACTIVATED CHARCOAL SLURRY MAY BE ADMINISTERED. TO
PREPARE ACTIVATED CHARCOAL SLURRY SUSPEND 50 GRAMS ACTIVATED
CHARCOAL ON 400 ML WATER IN PLASTIC BOTTLE AND SHAKE WELL.
ADMINISTER 5 ML/KG OR 350 ML FOR AVERAGE ADULT. BECAUSE OF DANGER
OF ASPIRATION, EMESIS OR GASTRIC LAVAGE SHOULD NOT BE EMPLOYED.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:118F,48C
Vapor Pres:334.1
Vapor Density:2.9
Spec Gravity:1.57
pH:NEUTRL
Evaporation Rate & Reference:>1 (CCL4=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR, COLORLESS LIQUID; SLIGHT ETHEREAL ODOR.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALKALI AND ALKALINE EARTH METALS-POWDERED ALUMINUM, ZINC, BERYLLIUM,
ETC.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:HYDROCHLORIC ACID, HYDROFLUORIC ACID
AND POSSIBLY CARBONYL HALIDES.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL ENVIRONMENTAL REGULATIONS. REMOVE TO A PERMITTED WASTE
DISPOSAL FACILITY. EPA HAZARDOUS WASTE NUMBERS F001 AND F002 MAY
APPLY TO WASTE MATERIALS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.