EASTMAN KODAK COMPANY -- 146 2845 GLACIAL ACETIC ACID -- 6750-01-387-4450
=====================  Product Identification  =====================

Product ID:146 2845 GLACIAL ACETIC ACID
MSDS Date:08/05/1995
FSC:6750
NIIN:01-387-4450
MSDS Number: BXCDL
=== Responsible Party ===
Company Name:EASTMAN KODAK COMPANY
Address:343 STATE STREET
City:ROCHESTER
State:NY
ZIP:14650
Country:US
Info Phone Num:716-722-5151 (TRANS: 800-242-2424)
Emergency Phone Num:716-722-5151
CAGE:19139
=== Contractor Identification ===
Company Name:EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
Address:343 STATE ST
Box:City:ROCHESTER
State:NY
ZIP:14650-1115
Country:US
Phone:716-722-5151/(800) 242-2424
CAGE:19139

=============  Composition/Information on Ingredients  =============

Ingred Name:ACETIC ACID (CERCLA)
CAS:64-19-7
RTECS #:AF1225000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:10 PPM
ACGIH TLV:10 PPM/15 STEL; 9495
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RAT) IS 3310 MG/KG
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION OF VAPOR EXTREMELY
    IRRITATING; MAY CAUSE DELAYED LUNG INJURY. CONTACT MAY CAUSE SEVERE
    SKIN AND EYE BURNS, SEVERE EYE IRRITATION. INGESTION MAY BE FATAL;
    MAY CAUSE BURNS TO GI TRACT.  CHRONIC: NONE SPECIFIED BY
    MANUFACTURER.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
    OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:INHALED-COUGHING, WHEEZING, CHEST PAIN,
    SHORTNESS OF BREATH. EYES-PAIN, TEARING, REDNESS, BURNS, BLURRED
    VISION. SKIN-REDNESS, PAIN, BURNS. INGESTED-ABDOMINAL PAIN, NAUSEA,
    VOMITING, DIARRHEA, BURNS T O MOUTH/THROAT/ESOPHAGUS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHALED-REMOVE TO FRESH AIR. GIVE OXYGEN IF CYANOTIC OR
    BREATHING DIFFICULT. GET MEDICAL ATTENTION. EYES: FLUSH WITH LOTS
    OF WATER FOR AT LEAST 15 MINUTES. CALL DOCTOR OR POISON CONTROL
    CENTER. SKIN-R EMOVE CLOTHES WHILE FLUSHING WITH WATER. GET MEDICAL
    ATTENTION. INGESTED-DO NOT INDUCE VOMITING! CALL A DOCTOR OR POISON
    CONTROL CENTER IMMEDIATELY! NOTHING BY MOUTH IF UNCONSCIOUS.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:103F,39C
Autoignition Temp:Autoignition Temp Text:960F
Lower Limits:6.6 %
Upper Limits:19.3 %
Extinguishing Media:USE WATER SPRAY, CARBON DIOXIDE, ALCOHOL FOAM, OR
    DRY CHEMICAL.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
    FULL PROTECTIVE GEAR. COOL FIRE EXPOSED CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:COMBUSTIBLE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ELIMINATE ALL SOURCES OF IGNITION. MAY REQUIRE
    NEUTRALIZATION IF PH <2.0. ABSORB SPILL WITH VERMICULITE OR OTHER
    INERT MATERIAL, THEN PLACE IN A CONTAINER FOR CHEMICAL WASTE. IF
    LARGE SPILL: FLUSH ARE A WITH WATER SPRAY. KEEP RUNOFF OUT OF
    SEWERS, ETC
Neutralizing Agent:DLA-HMIS: 20% SODIUM BICARBONATE SOLUTION.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP AWAY FROM TOXIC SUBSTANCES. KEEP
    CONTAINER CLOSED. KEEP AWAY FROM INCOMPATIBLE MATERIALS. DO NOT GET
    IN EYEE, ON SKIN OR CLOTHES.
Other Precautions:DO NOT BREATH VAPOR. USE ONLY WITH ADEQUATE
    VENTILATION. WASH THORROUGHLY AFTER HANDLING. KEEP AWAY FROM HEAT
    AND FLAME. KEEP FROM CONTACT WITH STRONG OXIDIZING AGENTS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
    OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH APPROVED RESPIRATOR OR
    AN AIR-SUPPLIED RESPIRATOR OR SCBA, AS REQUIRED. USE IN ACCORDANCE
    WITH 29 CFR 1910.13 4 AND MANUFACTURER'S RECOMMENDATIONS.
Ventilation:USE PROCESS CONTROL, LOCAL EXHAUST VENTILATION OR OTHER
    ENGINEERING CONTROLS TO MAINTAIN EXPOSURE BELOW TLV.
Protective Gloves:IMPERVIOUS: PVC, NEOPRENE.
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:EYE WASH STATION & SAFETY SHOWER, WASHING
    FACILITIES. IMPERVIOUS BOOTS & PROTECTIVE CLOTHING APPROPRIATE FOR
    RISK.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
    DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
THIS MATERIAL FORMS A STRONGLY ACIDIC AQUEOUS SOLUTION & MAY CAUSE
    ADVERSE ENVIRONMENTAL EFFECTS. IT HAS A HIGH BIOCHEMICAL OXYGEN
    DEMAND & A POTENTIAL TO CAUSE OXYGEN DEPLETION IN AQUEOUS SYSTEMS,
    A  LOW POTENTIAL TO AFFECT AQUATIC ORGANISMS. AFTER DILUTION WITH
    WATER, THIS MATERIAL WILL NOT HAVE A SIGNIFICANT IMPACT.

==================  Physical/Chemical Properties  ==================

HCC:F6
Boiling Pt:B.P. Text:239F,115C
Vapor Pres:18 MM HG
Vapor Density:0.6
Spec Gravity:1.05
pH:1.0
Viscosity:1.2 CPS @ 68F
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, COLORLESS LIQUID WITH A STRONG, PUNGENT,
    CHARACTERISTIC VINEGAR ODOR
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG BASES, METALS, AMINES.
Stability Condition to Avoid:HIGH HEAT, OPEN FLAMES AND OTHER SOURCES
    OF IGNITION
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL MAY BE SUBJECT
    TO NATIONAL, STATE OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE AMOUNTS
    OF WATER.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.