DEGUSSA CORP -- ALUMINUM OXIDE C -- 6810-00N057482
=====================  Product Identification  =====================

Product ID:ALUMINUM OXIDE C
MSDS Date:01/20/1994
FSC:6810
NIIN:00N057482
MSDS Number: BWQSH
=== Responsible Party ===
Company Name:DEGUSSA CORP
Address:65 CHALLENGER RD
City:RIDGEFIELD PK
State:NJ
ZIP:07660
Country:US
Info Phone Num:201-641-6100
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:8C791
=== Contractor Identification ===
Company Name:DEGUSSA CORP
Address:65 CHALLENGER RD
City:RIDGEFIELD PARK
State:NJ
ZIP:07660
Country:US
Phone:201-818-3706
CAGE:8C791

=============  Composition/Information on Ingredients  =============

Ingred Name:ALUMINUM OXIDE (2:3); (ALUMINUM OXIDE) (SARA 313)
CAS:1344-28-1
RTECS #:BD1200000
Fraction by Wt: >99.6%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50: >10,000 MG/KG.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE CONTACT:MAY CAUSE
    DISCOMFORT. SKIN:NOT EXPECTED TO BE AN IRRITANT. REPEATED OR
    PROLONGED CONTACT MAY CAUSE DERMATITIS & DEFATTING. NOT EXPECTED TO
    BE ABSORBED THROUGH SKIN. INHAL:MAY CAUSE P HYSICAL DISCOMFORT TO
    THE RESPIRATORY TRACT. INGEST:NOT EXPECTED TO BE TOXIC BY
    INGESTION. CHRONIC: (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:NO CHRONIC (LONG TERM) EFFECTS ARE
    KNOWN FOR HUMANS.
Medical Cond Aggravated by Exposure:MEDICAL CONDITIONS WHICH MAY BE
    AGGRAVATED BY EXPOSURE TO THIS PRODUCT INCLUDE: CONJUNCTIVITIS OF
    THE EYE, DERMATITIS OF THE SKIN, ASTHMA & RESPIRATORY DISEASES.

=======================  First Aid Measures  =======================

First Aid:INGEST:CALL MD IMMEDIATELY . EYE:FLUSH W/WATER FOR AT LEAST
    15 MINUTES. CALL MD IF DISCOMFORT PERSISTS. SKIN:WASH W/SOAP &
    WATER. CALL MD IF SYMPTOMS OCCUR. INHAL:REMOVE TO FRESH AIR. IF
    DISCOMF ORT PERSISTS, CALL MD.

=====================  Fire Fighting Measures  =====================

Flash Point:NON-FLAMMABLE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING
    FIRE CONDITIONS.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT . EVACUATE ENCLOSED & SURROUNDING AREAS.
Unusual Fire/Explosion Hazard:NONE KNOWN FOR THIS PRODUCT.

==================  Accidental Release Measures  ==================

Spill Release Procedures:FOR SMALL SPILLS, SWEEP OR SHOVEL SOLIDS INTO
    PROPER CONTAINER FOR DISPOSAL. CERCLA/SARA REQS NOTIFICATION TO
    APPROP FED, STATE & LOC AUTHS OF RELS OF HAZ/EXTREMELY HAZ QTYS
    EQUAL TO/GREATER THAN REPO RTABLE QTYS (RQS) IN 40 CFR 302.4 & 40
    CFR 355.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A WELL-VENTILATED, COOL & DRY
    AREA. WHEN NOT IN USE, KEEP CONTAINERS TIGHTLY CLOSED.
Other Precautions:PRIMARY PHYSIOLOGICAL EFT OF THIS PROD IS DRYING OF
    SKIN, WHICH CAN BE ELIM BY USING EXPOS CONTROL MEASURES REC & BY
    APPLYING LOTIONS & BARRIER CREAMS TO SKIN. FOR ADDNL PROD SFTY/PROD
    USE INFO, CONT  PROD MANAGER AT ADDRESS/PHONE # LISTED.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:ATMOSPHERIC LEVELS SHOULD BE MAINTAINED BELOW
    EXPOSURE LIMITS LISTED BY USING ENGINEERING CONTROLS. IF NOT
    FEASIBLE, USE A NIOSH/MSHA APPROVED AIR-PURIFYING RESPIRATOR
    W/APPROVED FILTERS &/OR SORBENTS .
Ventilation:PROVIDE GEN &/OR LOC EXHST VENT TO MAINTAIN AIRBORNE LEVELS
    BELOW EXPOS LIMITS. REFER TO "INDUS VENT" BY ACGIH (SUPDAT)
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:LOTIONS & BARRIER CREAMS ARE ALSO REC TO
    PVNT DRYING OF SKIN. IF RPTD/PRLNG SKIN CONT/CONTAM IS LIKELY, PROT
    (SUPP DATA)
Work Hygienic Practices:ESTABLISH GOOD PERSONAL HYGIENE & WORK
    PRACTICES. ALWAYS WASH HANDS & FACE BEFORE EATING, DRINKING OR
    SMOKING.
Supplemental Safety and Health
MATLS TO AVOID:IS INVOLVED W/STRONG ACIDS & STRONG BASES. VENT:FOR A
    MANUAL OF RECOMMENDED PRACTICES. OTHER PROT EQUIP:CLOTHING SHOULD
    BE WORN.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:5391F,2977C
Melt/Freeze Pt:M.P/F.P Text:3722F,2050C
Spec Gravity:3.2
pH:4-5.5
Solubility in Water:INSOLUBLE
Appearance and Odor:WHITE, FLUFFY POWDER W/NO ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
HAZ RXNS OCCUR WHEN THIS PROD IS INVOLVED W/CHLORINE
    TRIFLUORIDE/ETHYLENE OXIDE. CHEM RXNS OCCUR WHEN THIS PROD (SUPDAT)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE KNOWN.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF I/A/W ALL LOCAL, STATE & FEDERAL
    REGULATIONS. CONTACT DEGUSSA AT (205) 443-4000, EXT 2287 OR EXT
    2427 FOR ASSISTANCE W/DISPOSAL REQUIREMENTS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.