Product ID:PENETRATING OIL, 250-49
MSDS Date:07/01/1993
FSC:8010
NIIN:00N054545
MSDS Number: BVWRS
=== Responsible Party ===
Company Name:BRUNING PAINT CO
Address:601 S HAVEN ST
City:BALTIMORE
State:MD
ZIP:21224
Country:US
Info Phone Num:410-342-3636;410-342-3641
Emergency Phone Num:410-342-3636;410-342-3641
CAGE:EO376
=== Contractor Identification ===
Company Name:BRUNING PAINT COMPANY
Address:601 S. HAVEN STREET
City:BALTIMORE
State:MD
ZIP:21224
Country:US
Phone:800-424-9300(NIGHT)410-342-3636 DAY
CAGE:EO376
Company Name:KYANIZE PAINT
Address:601 S HAVEN ST
Box:City:BALTIMORE
State:MD
ZIP:21224
Country:US
Phone:800-368-2076
CAGE:85520

=============  Composition/Information on Ingredients  =============

Ingred Name:STODDARD SOLVENT
CAS:8052-41-3
RTECS #:WJ8925000
Fraction by Wt: 50-75%
OSHA PEL:500 PPM
ACGIH TLV:100 PPM

Ingred Name:TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (MAGNESIUM
    SILICATE)
CAS:14807-96-6
RTECS #:WW2710000
Fraction by Wt: 0-15%
OSHA PEL:2 MG/M3 RDUST
ACGIH TLV:2 MG/M3 RDUST

Ingred Name:SOLVENT NAPHTHA (PETROLEUM) MEDIUM ALIPHATIC; (HYDROCARBON
    SOLVENT)
CAS:64742-88-7
Fraction by Wt: 7.5-15%
OSHA PEL:2625 MG/M3 (MFR)
ACGIH TLV:525 MG/M3 (MFR)

Ingred Name:KEROSENE; (ALIPHATIC PETROLEUM SOLVENT)
CAS:8008-20-6
RTECS #:OA5500000
Fraction by Wt: 1-5%
OSHA PEL:2900 MG/M3 (MFR)
ACGIH TLV:525 MG/M3 (MFR)

Ingred Name:ETHYLENE GLYCOL  (SARA III)
CAS:107-21-1
RTECS #:KW2975000
Fraction by Wt: 0.4-6.7%
Other REC Limits:N/K 
OSHA PEL:N/K 
ACGIH TLV:50 PPM, VAPOR, C
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:VOLATILE ORGANIC COMPONENT: 5.79-5.85.
RTECS #:9999999VO

Ingred Name:SUPDAT:PREVENT VAPOR PRESSURE BUILDUP WHICH COULD RESULT IN
    CONTAINER RUPTURE.
RTECS #:9999999ZZ

Ingred Name:HAZ DECOMP PROD:OXIDES OF NITROGEN.
RTECS #:9999999ZZ

Ingred Name:FIRST AID PROC:UNLESS ADVISED BY MD. CONTACT MD
    IMMEDIATELY.
RTECS #:9999999ZZ

Ingred Name:SPILL PROC:NOTIFY LOCAL HEALTH & POLLUTION CONTROL
    AGENCIES. CALL SPILL RESPONSE TEAMS IF SPILL IS LARGE.
RTECS #:9999999ZZ

Ingred Name:RESP PROT:OF PARTICULATE & GAS & VAP. IN CONFINED AREAS,
    USE NIOSH/MSHA APPRVD AIR LINE TYPE RESPS/HOODS. RESP (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11:PROT MAY ALSO BE NEC IN ANY LATER MFG OPERATIONS IN
    WHICH THESE PRODS MAY BECOME AIRBORNE IN FORM OF VAP/DUST.
RTECS #:9999999ZZ

Ingred Name:VENT:APPRVD RESP TO PVNT OVEREXP. PROVIDE GEN DILUTION/LOC
    EXHST VENT IN VOL & PATTERN TO KEEP TLV OF MOST HAZ (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:INGS BELOW ACCEPT LIM, LEL BELOW STATED LIM & TO
    REMOVE DECOMP PRODS DURING WELDING/FLAME CUTTING ON (ING 15)
RTECS #:9999999ZZ

Ingred Name:ING 14:SURFACES COATED W/THESE PRODUCTS.
RTECS #:9999999ZZ

Ingred Name:PROT GLOVES:RUBBER, NEOPRENE, BUNA N OR NITRILE.
RTECS #:9999999ZZ

Ingred Name:HYGIENE PRACT:PROPERLY LAUNDERED.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:REPORTS HAVE ASSOCIATED REPEATED &
    PROLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS W/PERMANENT BRAIN &
    NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE BY DELIBERATELY
    CONCENTRATING & INHALING CONTENTS MAY B E HARMFUL/FATAL. DO NOT
    BREATHE VAPORS/SPRAY MIST, WEAR APPROP, PROPERLY FITTED NIOSH/MSHA
    APPRVD RESP (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:DURING & AFTER APPLICATION UNLESS AIR
    MONITORING DEMONSTRATES VAP/MIST LEVELS ARE BELOW APPLIC LIMS.
    FOLLOW RESP MFR'S DIRECTIONS FOR RESP USE. ING 1,3,4,5:PRODS MAY
    CAUSE NOSE, THROAT & EYE  IRRIT. SYMPS OF OVEREXP INCL DIZZ, HDCH,
    INTOX W/EUPHORIA LEADING TO UNCON.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYE:FLUSH W/LUKE WARM WATER FOR AT LST 15 MINS. SEEK MD
    IMMED. SKIN:FLUSH WASH W/COPIOUS AMTS OF LUKE WARM WATER. REMOVE
    CONTAM CLTHG PROMPTLY. IF IRRIT OCCURS, GET MED ATTN. INHAL:REMOVE
    EXPOS INDIVI DUAL TO FRESH AIR. RESTORE BRTHG IF REQD. CONT MD
    IMMED. INGEST:RINSE MOUTH IMMED. GIVE EXPOS INDIVIDUALS 6-8 OZS OF
    LIQ. (NEVER GIVE ANYTHING BY MOUTH TO UNCON PERS.) DO NOT INDUCE
    VOMIT (ING 9)

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:104F,40C
Lower Limits:0.9%
Upper Limits:7%
Extinguishing Media:NFPA CLASS B EXTINGUISHER IS DESIGNED TO EXTINGUISH
    CLASS IB FLAMMABLE LIQUID FIRES.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
    WATER SPRAY MAY BE INEFT. WATER MAY BE USED TO COOL CLSD CNTNRS TO
    PVNT PRESS BUILDUP & POSS AUTO- (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
    HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
    EXPOS TO EXTREME HEAT. DO NOT APPLY TO HOT (SUPP DATA)

==================  Accidental Release Measures  ==================

Spill Release Procedures:STOP &/OR CONTAIN DISCHARGE IF IT MAY BE DONE
    SAFELY. KEEP ALL SOURCES OF IGNIT AWAY. VENTILATE AREA OF SPILL.
    USE NON-SPARKING TOOLS FOR CLEANUP. COVER W/INERT MATL TO REDUCE
    FUMES. KEEP OUT OF DRAIN S, SEWERS/WATERWAYS. CONT FIRE AUTHS. (ING
    10)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT STORE >120F. GROUND CNTNRS WHEN
    POURING & LIM FREE-FALL TO A FEW INCHES TO PVNT STATIC SPKS. KEEP
    CNTNR TIGHTLY CLSD WHEN NOT IN USE.
Other Precautions:AVOID SPONT COMBUST OF CONTAM RAGS/OTHER EASILY
    IGNITABLE ORG MATLS BY IMMED IMMERSION IN WATER. EMPTIED CNTNRS MAY
    CONTAIN HAZ PROPERTIES. DO NOT CUT/PUNCTURE CNTNR. DO NOT WELD NEAR
    CNTNR. USE ONLY  W/ADEQ VENT. AVOID CONT W/EYES.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IN OUTDOOR/OPEN AREAS, USE NIOSH/MSHA APPRVD
    MECH FILTER RESP TO REMOVE SOLID AIRBORNE PARTICLES OF OVERSPRAY
    DURING SPRAY APPLICATION. IN RESTRICTED VENT AREAS, USE NIOSH/MSHA
    APPRVD CHEM MECH FILTER S DESIGNED TO REMOVE COMBINATION(ING 11)
Ventilation:USE VENT AS REQD TO CONTROL VAP CONCS. AVOID PRLNG/RPTD
    BRTHG OF VAPS. IF EXPOS EXCEEDS TLV, USE NIOSH/MSHA (ING 13)
Protective Gloves:RESIST GLOVES SUCH AS NATURAL (ING 16)
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:AN APRON SHOULD BE WORN TO AVOID SKIN
    CONTACT.
Work Hygienic Practices:WASH HANDS THORO BEFORE EATING & USING
    WASHROOM. REMOVE CONTAM CLTHG IMMED & DO NOT WEAR IT UNTIL IT HAS
    BEEN (ING 17)
Supplemental Safety and Health
% VOLAT:87.05-89.08. FIRE FIGHT PROC:IGNIT/EXPLO WHEN EXPOS TO EXTREME
    HEAT. IF WATER IS USED, FOG NOZZ ARE PREF. EXPLO HAZ:SURFS. NEVER
    USE WELDING/CUTTING TORCH ON/NEAR CNTNR (EVEN EMPTY) BECAUSE PR OD
    (EVEN RESIDUE) MAY IGNITE EXPLOSIVELY. CNTNRS EXPOS TO INTENSE HEAT
    FROM FIRES SHOULD BE COOLED W/WATER TO (ING 7)

==================  Physical/Chemical Properties  ==================

HCC:F4
Boiling Pt:B.P. Text:>300F,>149C
Vapor Pres:2 @ 68F
Vapor Density:HVR/AIR
Spec Gravity:0.87-0.95
Evaporation Rate & Reference:SLOWER/BUTYL ACETATE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:AVOID EXPOSURE TO SPARKS, OPEN FLAME, HOT
    SURFACES & ALL SOURCES OF HEAT & IGNITION.
Hazardous Decomposition Products:MAY PRODUCE HAZ FUMES WHEN HEATED TO
    DECOMP AS IN WELDING. FUMES MAY CONTAIN CARBON MONOXIDE, CARBON
    DIOXIDE & (ING 8)

====================  Disposal Considerations  ====================

Waste Disposal Methods:DO NOT FLUSH TO SEWER, WATERSHED OR WATERWAY.
    DISPOSE OF THESE PRODUCTS I/A/W APPLICABLE LOCAL, COUNTY, STATE &
    FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their