E I DU PONT DE NEMOURS & CO -- FREON 115 REFRIGERANT -- 6830-00N044636
===================== Product Identification =====================
Product ID:FREON 115 REFRIGERANT
MSDS Date:04/28/1992
FSC:6830
NIIN:00N044636
MSDS Number: BSCDL
=== Responsible Party ===
Company Name:E I DU PONT DE NEMOURS & CO
Address:1007 MARKET ST
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-9442
Emergency Phone Num:800-441-3637;800-424-9300(CHEMTREC)
CAGE:B0589
=== Contractor Identification ===
Company Name:E I DU PONT DE NEMOURS & CO
Address:RAKETSTRAAT, 100, RUE DE LA FUSEE
City:BRUSSEL
Country:BE
Phone:32-(0)15-401.505
CAGE:B0589
Company Name:E.I. DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515;800-441-9442
CAGE:18873
============= Composition/Information on Ingredients =============
Ingred Name:ETHANE, CHLOROPENTAFLUORO-; ("FREON" 115) (SARA III)
CAS:76-15-3
RTECS #:KH7877500
Fraction by Wt: 100%
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM
Ozone Depleting Chemical:1
Ingred Name:SUPDAT:INGEST INCL MILD DIARR, SALIVATION & INCR ACTIVITY.
NO ANIMAL TEST RPTS ARE AVAIL TO DEFINE CARCIN DEVEL/ (ING 3)
RTECS #:9999999ZZ
Ingred Name:ING 2:REPRO HAZS. CMPD DOES NOT PRDCE GENETIC DMG IN
BACTERIAL CELL CULTURES BUT HAS NOT BEEN TESTED IN ANIMALS.
RTECS #:9999999ZZ
Ingred Name:FIRST AID PROC:AS EPINEPHRINE, SHOULD BE USED W/SPECIAL
CAUTION IN SITUATIONS OF EMERGENCY LIFE SUPPORT.
RTECS #:9999999ZZ
Ingred Name:VENT:SHOULD BE USED IN LOW PLACES.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL OF HIGH CONCS OF VAP IS HARMFUL
& MAY CAUSE HEART IRREGS, UNCON/DEATH. INTENTIONAL MISUSE/DELIB
INHAL MAY CAUSE DEATH W/OUT WARNING. VAP REDUCES OXYGEN AVAIL FOR
BRTHG & IS HVR/AIR. LIQ CONT CAN CAUSE FROSTBITE. INHAL OF HIGH
CONCS MAY INCL TEMPORARY NERV SYS DEPRESS W/ANESTH EFTS SUCH AS
DIZZ, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:HDCH, CONFUSN, INCOORD & LOSS OF
CONSCIOUSNESS; TEMPORARY ALTERATION OF HEART'S ELEC ACTIVITY
W/IRREG PULSE, PALPITATIONS/INADEQ CIRCULATION. SKIN/EYE CONT MAY
INCL FROSTBITE IF CONT W/LIQ OC CURS. ANIMAL DATA:CMPD IS UNTESTED
FOR SKIN/EYE IRRITANCY & FOR ANIMAL SENSIT. EFTS OF SINGLE INHAL
EXPOS AT (SUPDAT)
Medical Cond Aggravated by Exposure:INDIVIDUALS W/PREEXISTING DISEASES
OF THE CENTRAL NERVOUS SYSTEM OR CARDIOVASCULAR SYSTEM MAY HAVE
INCREASED SUSCEPTIBILITY TO TOXICITY OF EXCESSIVE EXPOSURES.
======================= First Aid Measures =======================
First Aid:INGEST:CALL MD IMMED . INHAL:IMMED REMOVE TO FRESH AIR. KEEP
PERS CALM. IF NOT BRTHG, GIVE ARTF RESP. IF BRTHG IS DFCLT, GIVE
OXYGEN. CALL MD. SKIN:IMMED FLUSH W/WATER FOR 15 MINS. TREAT FOR
FRO STBITE IF NEC BY GENTLY WARMING AFFECTED AREA. EYE:IMMED FLUSH
W/PLENTY OF WATER FOR AT LST 15 MINS. CALL MD. NOTES TO MD:BECAUSE
OF POSS DISTURB OF CARDIAC RHYTHM, CATECHOLAMINE DRUGS, SUCH (ING
4)
===================== Fire Fighting Measures =====================
Flash Point:WILL NOT BURN
Extinguishing Media:AS APPROPRIATE FOR COMBUSTIBLES IN AREA.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:USE WATER SPRAY/FOG TO COOL CNTNRS. CYLS
ARE EQUIPPED W/PRESS & TEMP RELIEF DEVICES, BUT MAY STILL RUPTURE
UNDER FIRE CNDTNS. DECOMP MAY OCCUR.
================== Accidental Release Measures ==================
Spill Release Procedures:NOTE:REVIEW FIRE & EXPLO HAZS & SFTY PRECS
BEFORE PROCEEDING W/CLEAN UP. USE APPROP PERSONAL PROT EQUIP DURING
CLEAN UP. VENT AREA-ESP LOW PLACES WHERE HEAVY VAPS MIGHT COLLECT.
REMOVE OPEN FLAMES. NI OSH/MSHA APPRVD SCBA IS REQD IF LG SPILL
OCCURS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STOR CNDTNS:CLEAN, DRY AREA. DO NOT
HEAT >125F. AVOID BRTHG VAPS & LIQ CONT W/SKIN OR EYES. USE
SUFFICIENT VENT TO KEEP EMPLOYEE EXPOS BELOW REC LIMS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:UNDER NORMAL MANUFACTURING CONDITIONS, NO
RESPIRATORY PROTECTION IS REQUIRED WHEN USING THIS PRODUCT.
NIOSH/MSHA APPROVED SCBA IS REQUIRED IF A SPILL OCCURS.
Ventilation:NORMAL VENT FOR STD MFG PROCS IS GENERALLY ADEQ. LOC EXHST
SHOULD BE USED WHEN LG AMTS ARE RELEASED. MECH VENT (ING 5)
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEM WORK GOGG .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VP:132 PSIA @ 25C. HAZ DECOMP PROD:ETC) FORMING HYDROCHLORIC &
HYDROFLUORIC ACIDS & POSS CARBONYL HALIDES. EFTS OF OVEREXP:HIGH
CONCS INCL RAPID RESP & INACTIVITY. RPTD EXPOS AT LOWER LEVELS
PRDCD NO SIGNS OF TOX. EXPOS TO 150,000 PPM W/SIMULTANEOUS
EPINEPHRINE CHALLENGE PRDCD CARDIAC ARRHY IN DOGS. EFTS OF RPTD(ING
2)
================== Physical/Chemical Properties ==================
HCC:G3
Boiling Pt:B.P. Text:-38F,-39C
Vapor Pres:SUPP DATA
Vapor Density:5.6
Evaporation Rate & Reference:>1 (CCL4=1)
Solubility in Water:0.006 WT% @ 25C
Appearance and Odor:CLEAR, COLORLESS, LIQUEFIED GAS; SLIGHT ETHEREAL
ODOR.
Percent Volatiles by Volume:100 WT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE W/ALKALI OR ALKALINE EARTH METALS-POWDERED AL, ZN, BE,
ETC.
Stability Condition to Avoid:AVOID OPEN FLAMES & HIGH TEMPERATURES.
Hazardous Decomposition Products:DECOMP PRODS ARE HAZ. "FREON" 115
FLUOROCARBON CAN BE DECOMPOSED BY HIGH TEMPS(OPEN FLAMES, GLOWING
METAL SURFS,(SUPDAT)
==================== Disposal Considerations ====================
Waste Disposal Methods:COMPLY W/FEDERAL, STATE & LOCAL REGULATIONS.
RECLAIM BY DISTILLATION OR REMOVE TO A PERMITTED WASTE DISPOSAL
FACILITY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.