MARK V LABORATORY INC -- DIAMOND PASTE WATERBASE, DPW2-6 -- 6850-00N043834
=====================  Product Identification  =====================

Product ID:DIAMOND PASTE WATERBASE, DPW2-6
MSDS Date:05/16/1991
FSC:6850
NIIN:00N043834
MSDS Number: BRZSJ
=== Responsible Party ===
Company Name:MARK V LABORATORY INC
Box:540
City:EAST GRANBY
State:CT
ZIP:06026-9720
Country:US
Info Phone Num:203-653-7201
Emergency Phone Num:203-653-7201
CAGE:6U350
=== Contractor Identification ===
Company Name:MARK V LABORATORY
Address:18 KRIPES RD
Box:City:EAST GRANBY
State:CT
ZIP:06026
Country:US
Phone:203-653-7201
CAGE:6U350

=============  Composition/Information on Ingredients  =============

Ingred Name:GLYCOLS, POLYETHYLENE POLYPROPYLENE, MONOBUTYL ETHER
    (NONIONIC); (POLYALKYLENE GLYCOL)
CAS:9038-95-3
RTECS #:MD0911000
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:POLYETHYLENE GLYCOL
CAS:25322-68-3
RTECS #:TQ3500000
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:FATTY ACID ESTER 2; (FATTY ACID ESTER)
CAS:61791-00-2
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SILICA; (COLLOIDAL SILICA)
CAS:112945-52-5
RTECS #:VV7310000
OSHA PEL:6 MG/M3
ACGIH TLV:10 MG/M3 TDUST

Ingred Name:DIAMOND
CAS:7782-40-3
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHAL/INGEST:NO EVIDENCE OF ADVERSE
    EFFECTS. SKIN:MAY CAUSE IRRITATION & REDDENING. EYE:CAUSES MODERATE
    TO SEVERE IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
    SKIN:WASH W/SOAP & WATER. EYE:FLUSH THOROUGHLY W/WATER FOR AT LEAST
    15 MINUTES, SEEK MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:200F,93C
Lower Limits:0.5%
Upper Limits:1.8%
Extinguishing Media:CO2 OR DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE

==================  Accidental Release Measures  ==================

Spill Release Procedures:SMALL SPILLS CAN BE FLUSHED W/LARGE AMOUNTS OF
    WATER, LARGER SPILLS SHOULD BE COLLECTED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID OPEN FLAMES, STRONG ACIDS &
    TEMPERATURES EXCEEDING 200F. WASH THOROUGHLY AFTER HANDLING!
Other Precautions:USE ADEQUATE VENTILATION, WASH HANDS. AVOID SMOKING
    &/OR OPEN FLAME.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN .
Ventilation:LOCAL: AVOID CONFINED SPACES. MECHANICAL (GENERAL): GENERAL
    FACTORY FAN.
Protective Gloves:PVC-COATED GLOVES.
Eye Protection:ANSI APPD SAFETY GOGGLES.
Other Protective Equipment:EYE BATH & SAFETY SHOWER AVAILABLE.
Work Hygienic Practices:WASH HANDS W/SOAP & WATER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:>350F,>177C
Vapor Pres:0.001 @20C
Spec Gravity:0.991
Solubility in Water:SOLUBLE
Appearance and Odor:TRANSLUCENT; LOW ODOR.
Percent Volatiles by Volume:0

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID STRONG BASES AT HIGH TEMPERATURES, STRONG ACIDS, STRONG OXIDIZING
    AGENTS & MATLS REACTIVE W/HYDROXYL COMPOUND.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:BURNING MAY PRODUCE CARBON DIOXIDE,
    CARBON MONOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:INCINERATE IN A FURNACE WHERE PERMITTED UNDER
    APPROPRIATE FEDERAL, STATE & LOCAL REGULATION.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their