SYSTEMS SCIENTIFIC LABORATORIES INC -- AMMONIUM ACETATE SOLUTION -- 6810-00N018168
===================== Product Identification =====================
Product ID:AMMONIUM ACETATE SOLUTION
MSDS Date:12/03/1990
FSC:6810
NIIN:00N018168
MSDS Number: BLWPK
=== Responsible Party ===
Company Name:SYSTEMS SCIENTIFIC LABORATORIES INC
Address:1295 BOULEVARD WAY
City:WALNUT CREEK
State:CA
ZIP:94595
Country:US
Info Phone Num:415-937-6748
Emergency Phone Num:415-937-6748
Preparer's Name:JAMES P GILLEENY
CAGE:3R657
=== Contractor Identification ===
Company Name:SYSTEMS SCIENTIFIC LAB INC
Address:1295 BOULEVARD WAY
Box:City:WALNUT CREEK
State:CA
ZIP:94595
Country:US
Phone:415-937-6748
CAGE:3R657
============= Composition/Information on Ingredients =============
Ingred Name:ACETIC ACID, AMMONIUM SALT; (AMMONIUM ACETATE SOLUTION)
CAS:631-61-8
RTECS #:AF3675000
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE SKIN AND EYE IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:SKIN/EYE CONTACT: FLUSH WITH PLENTY OF WATER FOR A MINIMUM OF
15 MINUTES. INGEST: CALL MD IMMEDIATELY . INHAL: REMOVE TO FRESH
AIR. SUPPORT BREATHING (GIVE O2/ARTF RESP) .
===================== Fire Fighting Measures =====================
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:EMITS AMMONIA ON DECOMPOSITION.
================== Accidental Release Measures ==================
Spill Release Procedures:COLLECT INTO SUITABLE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE. IF NECESSARY, USE NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL & MECHANICAL (GENERAL) - ACCEPTABLE.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:DECOMPOSES
Melt/Freeze Pt:M.P/F.P Text:237F,114C
Spec Gravity:1.07
Solubility in Water:148%
Appearance and Odor:WHITE CRYSTALS.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
CONTACT WITH CAUSTIC LIBERATES AMMONIA.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:LIBERATES AMMONIA ON DECOMPOSITION.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF BY MEANS AS TO COMPLY WITH ALL LOCAL,
STATE, AND FEDERAL REGULATIONS OR CONTACT AN APPROVED & LICENSED
DISPOSAL AGENCY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.