ASHLAND CHEMICAL COMPANY -- NOVASET 735 -- 8030-00N014781
=====================  Product Identification  =====================

Product ID:NOVASET 735
MSDS Date:12/22/1988
FSC:8030
NIIN:00N014781
MSDS Number: BKNJR
=== Responsible Party ===
Company Name:ASHLAND CHEMICAL COMPANY
Box:2219
City:COLUMBUS
State:OH
ZIP:43216-2219
Country:US
Info Phone Num:614-889-3333
Emergency Phone Num:606-324-1133
CAGE:34897
=== Contractor Identification ===
Company Name:ASHLAND CHEMICAL CO
Box:2219
City:COLUMBUS
State:OH
ZIP:43216-2219
Country:US
Phone:614-790-3333/800-274-5263
CAGE:34897

=============  Composition/Information on Ingredients  =============

Ingred Name:POTASSIUM HYDROXIDE  (SARA III)
CAS:1310-58-3
RTECS #:TT2100000
Fraction by Wt: 1-5%
OSHA PEL:C, 2 MG/M3
ACGIH TLV:C 2 MG/M3; 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:FORMALDEHYDE  (SARA III)
CAS:50-00-0
RTECS #:LP8925000
Fraction by Wt: 0.2%
OSHA PEL:SEE 1910.1048
ACGIH TLV:C 0.3 PPM; A2; 9293
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Ingred Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 40-45%

Ingred Name:FIRST AID PROC: MILK OF MAGNESIA. KEEP WARM, QUIET. GET MED
    ATTN IMMED. BRTHG: REMOVE INDIVIDUAL TO FRESH AIR. (ING 06)
RTECS #:9999999ZZ

Ingred Name:ING 05: KEEP PERSON WARM, QUIET, AND GET MEDICAL ATTENTION.
RTECS #:9999999ZZ

Ingred Name:SPILL PROC: FLAMES INCLUDING PILOT LIGHTS, ELEC SPARKS).
    PERSONS NOT WEARING PROT EQUIP SHOULD BE EXCLUDED FROM (ING 08)
RTECS #:9999999ZZ

Ingred Name:ING 07: AREA OF SPILL UNTIL CLEAN UP HAS BEEN COMPLETED.
    LIQ MAY BE TAKEN UP ON SAND, CLAY, EARTH, FLOOR ABSORB,(ING 09)
RTECS #:9999999ZZ

Ingred Name:ING 08: OR OTHER ABSORBENT MATERIAL AND SHOVELED INTO
    CONTAINERS.
RTECS #:9999999ZZ

Ingred Name:RESP: ENGINEERING OR ADMINISTRATIVE CONTROLS SHOULD BE
    IMPLEMEMTED TO REDUCE EXPOSURE.
RTECS #:9999999ZZ

Ingred Name:PHENOLIC RESIN SALT
Fraction by Wt: 50-55%

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:YES
Health Hazards Acute and Chronic:ACUTE: EYES: CAUSES BURNS. SKIN:
    PROLONGED OR REPEATED CONTACT CAN CAUSE IRRITATION, DEFATTING,
    DERMATITIS, BURNS; POSSIBLE SENSITIZATION. INHAL: CAN CAUSE
    MODERATE TO SEVERE EYE, NOSE, THROAT & RESPI RATORY TRACT
    IRRITATION. INGEST: RESULTS IN SEVERE DAMAGE TO MUCOUS MEMBRANES
    AND DEEP TISSUES. (SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:FORMALDEHYDE: GROUP 2A (IARC), GROUP 2
    (NTP), OSHA REGULATEDCARCINOGEN
Effects of Overexposure:HLTH HAZ: CHRONIC: THIS MATERIAL (OR ITS
    COMPONENTS) HAS BEEN SUGGGESTED AS A CAUSE OF SKIN SENSITIZATION IN
    HUMANS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:SKIN: IMMED FLUSH W/WATER FOR AT LEAST 15 MIN, GET MED ATTN.
    REMOVE CONTAM CLTHG. LAUNDER BEFORE REUSE. REMOVE CONTAM SHOES
    PROMPTLY. DISCARD SHOES SATURATED W/PROD. EYES: IMMED FLUSH W/LG
    AMTS OF WAT ER FOR AT LEAST 15 MIN. LIFT UPPER/LOWER LIDS OCCASN.
    GET IMMED MED ATTN. INGEST: DO NOT INDUCE VOMITING. VOMITING WILL
    CAUSE FURTHER DMG TO THE THROAT. DILUTE BY GIVING WATER. GIVE (SEE
    INGRED 05)

=====================  Fire Fighting Measures  =====================

Flash Point Method:SCC
Flash Point:130F,54C
Extinguishing Media:REGULAR FOAM, WATER FOG, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA W/FULL FACEPIECE
    OPERATED IN THE POSITIVE PRESSURE DEMAND MODE WITH FULL PROTECTIVE
    EQUIPMENT  WHEN FIGHTING FIRES.
Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR AND MAY
    TRAVEL ALONG THE GROUND OR BE MOVED BY VENTILATION AND IGNITED BY
    HEAT, PILOT LIGHTS, OTHER FLAMES AND (SEE SUPP DATA)

==================  Accidental Release Measures  ==================

Spill Release Procedures:SM SPILL: ELIM ALL SOURCES OF IGNITION SUCH AS
    FLARES, FLAMES (INCLUDING PILOT LIGHTS), & ELEC SPARKS. ABSORB LIQ
    ON PAPER, VERMICULITE, FLOOR ABSORB, OR OTHER ABSORB MATL &
    TRANSFER TO HOOD. LG SPILL : ELIM ALL IGNIT SOURCES (FLARES, (SEE
    INGRED 07)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:CONTAINERS OF THIS MATERIAL MAY BE
    HAZARDOUS WHEN EMPTIED. SINCE EMPTIED CONTAINERS RETAIN PRODUCT
    RESIDUES (VAPOR, LIQUID, AND/OR (SEE OTHER PREC)
Other Precautions:HNDLG/STOR PREC: SOLID), ALL HAZARD PRECAUTIONS GIVEN
    MUST BE OBSERVED.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF WORKPLACE EXPOS LIM OF PROD OR ANY COMPONENT
    IS EXCEEDED, A NIOSH/MSHA APPRVD AIR SUPP RESP IS ADVISED IN
    ABSENCE OF PROP ENVIRON CTL. OSHA REGS ALSO PERMIT OTHER NIOSH/MSHA
    RESPS (NEG PRESS TYPE)  UNDER SPECIFIED CNDTNS. (SEE INGRED 10)
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL AND/OR LOCAL
    EXHAUST) VENTILATION TO MAINTAIN EXPOSURE BELOW TLVS.
Protective Gloves:RESISTANT: POLYETHYLENE.
Eye Protection:CHEM WORK GOGGLES /FULL LGTH FSHLD
Other Protective Equipment:WEAR IMPERVIOUS CLOTHING AND BOOTS TO
    PREVENT SKIN CONTACT, EYE WASH STATION, EMERGENCY SHOWER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ: IGNITION SOURCES AT LOCATIONS DISTANT FROM MATERIAL HNDLG
    POINT. NEVER USE WELDING/CUTTING TORCH ON/NEAR DRUM (EVEN EMPTY)
    BECAUSE PROD (EVEN RESIDUE) CAN IGNITE EXPLOSIVELY. ALL 5 GAL PAIL
    S & LARGER METAL CONTAINERS INCLUDING TANK CARS/TANK TRUCKS SHOULD
    BE GROUNDED AND/OR BONDED WHEN MATL IS TRANSFERRED.

==================  Physical/Chemical Properties  ==================

HCC:F4
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:17.5 @ 20C
Vapor Density:> AIR
Spec Gravity:1.250 @ 25C
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:CLEAN, DARK RED LIQUID
Percent Volatiles by Volume:12-13

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG MINERAL ACIDS, STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY FORM TOXIC MATERIALS: CO*2 AND CO,
    VARIOUS HYDROCARBONS, ALDEHYDES, PHENOLS, ETC.

====================  Disposal Considerations  ====================

Waste Disposal Methods:SM SPILL: ALLOW VOLAT PORTION TO EVAP IN HOOD.
    ALLOW SUFFICIENT TIME FOR VAPS TO COMPLETELY CLEAR HOOD DUCT WORK.
    DISP OF REMAINING MATL I/A/W FED, STATE & LOCAL REGS . LG SPILL:
    DESTROY BY LIQ  INCINERATION I/A/W FED, STATE & LOCAL REGS .

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.