CHEVRON ENVIRONMENTAL HEALTH CENTER INC. -- CHEVRON RPM DELO MOTOR OIL SAE 10W-30 -- 9150-00-186-6703
=====================  Product Identification  =====================

Product ID:CHEVRON RPM DELO MOTOR OIL SAE 10W-30
MSDS Date:12/11/1990
FSC:9150
NIIN:00-186-6703
MSDS Number: BHXXJ
=== Responsible Party ===
Company Name:CHEVRON ENVIRONMENTAL HEALTH CENTER INC.
Address:15299 SAN PABLO AVE.
Box:4054
City:RICHMOND
State:CA
ZIP:94804
Country:US
Info Phone Num:800-582-3835
Emergency Phone Num:800-457-2022 OR 415-233-3737
CAGE:0AHD1
=== Contractor Identification ===
Company Name:CHEVRON ENVIRONMENTAL HEALTH CENTER INC
Address:15299 SAN PABLO AVE
Box:4054
City:RICHMOND
State:CA
ZIP:94804
Country:US
Phone:800-582-3835
CAGE:0AHD1

=============  Composition/Information on Ingredients  =============

Ingred Name:LUBRICATING BASE OIL (THE BASE OIL MAY BE MIXTURE OF
    SEVERAL PETROLEUM BASE STOCKS)
Fraction by Wt: >75%
Other REC Limits:NONE SPECIFIED
OSHA PEL:5MG/CUM OIL MIST
ACGIH TLV:5MG/CUM OIL MIST

Ingred Name:ZINC ALKYL DITHIOPHOSPHATE
CAS:68649-42-3
Fraction by Wt: <1.5%
Other REC Limits:NONE SPECIFIED

Ingred Name:ADDITIVES INCLUDING ZINK ALKYL DITHIOPHOSPHATE
Fraction by Wt: <25%
Other REC Limits:NONE SPECIFIED

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:THIS SUBSTANCE IS NOT EXPECTED TO
    CAUSE PROLONGED OR SIGNIFICANT EYE OR SKIN IRRITATION. THE SYSTEMIC
    TOXICITY OF THIS SUBSTANCE HAS NOT BEEN DETERMINED. HOWEVER, IT
    SHOULD BE PRACTICALLY NON-TOXIC TO	INTERNAL ORGANS IF IT GETS ON
    THE SKIN, IS INHALED, OR IS INGESTED.
Explanation of Carcinogenicity:NONE OF THE COMPOUNDS IN THIS PRODUCT IS
    LISTED BY IARC, NTP, OR OSHA AS A CARCINOGEN.
Effects of Overexposure:CHEVRON MSDS SPECIFICALLY STATES IN ITS SECTION
    3 "IMMEDIATE HEALTH EFFECTS" THAT THE TOXICITY OF THIS SUBSTANCE
    HAS NOT BEEN DETERMINED TO CAUSE PROBLEMS ON EYE CONTACT,AS SKIN
    IRRITANT,ON DERMAL TOX ICITY,RESPIRATORY/INHALATION AND INGESTION
    TRACTS.FURTHERMORE,THIS EVALUATION IS BASED ON DATA FROM SIMILAR
    MATERIALS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:NO FIRST AID PROCEDURES ARE REQUIRED IF PRODUCT COMES IN
    CONTACT WITH EYES, SKIN OR IS BREATHED. FOR PRECAUTIONARY MEASURES
    COMPLETELY WASH EYES AND SKIN. IF SWALLOWED, GIVE WATER OR MILK TO
    DRINK AND  TELEPHONE FOR MEDICAL ADVICE. CONSULT MEDICAL PERSONNEL
    BEFORE INDUCING VOMITING.IF MEDICAL ADVICE CANNOT BE OBTAINED,THEN
    TAKE THE PRODUCT CONTAINER AND PERSON TO THE NEAREST MEDICAL
    FACILITY.

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:401F,205C
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, ALCOHOL FOAM, OR DRY
    CHEMICAL.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCB &
    FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
    SPRAY TO CO NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE PRODUCTI
    OF HAZARDOUS DECOMPOSITION PRODUCTS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:STOP THE SOURCE OF THE LEAK OR RELEASE.CLEAN
    UP RELEASES AS SOON AS POSSIBLE.CONTAIN THE LIQUID TO PREVENT
    FURTHER CONTAMINATION OF SOIL,SURFACE WATER OR GROUNDWATER.CLEAN UP
    SMALL SPILL WITH ABSORBEN T MATERIALS OR PUMPING ALSO REMOVE
    CONTAMNTD SOIL.
Neutralizing Agent:NOT APPLICABLE.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED
    AREA. KEEP CONTAINERS TIGHTLY CLOSED WHEN NOT IN USE. PROTECT
    CONTAINERS FROM PHYSICAL DAMAGE.
Other Precautions:DO NOT USE PRESSURE TO EMPTY CONTAINERS OR EXPLOSION
    MAY RESULT. DO NOT WELD, HEAT OR DRILL CONTAINER. RESIDUE MAY
    IGNITE WITH EXPLOSIVE VIOLENCE IF HEATED SUFFICIENTLY.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NO SPECIAL RESPIRATORY PROTECTION IS NORMALLY
    REQUIRED. HOWEVER, USE APPROVED RESPIRATOR IF AIRBORNE
    CONCENTRATIONS ARE ABOVE THE LIMITS.
Ventilation:USE ADEQUATE VENTILATION TO KEEP THE AIRBORNE
    CONCENTRATIONS OF THIS MATERIAL BELOW THE RECOMMENDED EXPOSURE
    STANDARD.
Protective Gloves:NOT NORMALLY REQUIRED.
Eye Protection:NOT NORMALLY REQUIRED.
Other Protective Equipment:AVOID PROLONGED OR REPEATED CONTACT.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
    RECOMMENDED PROCEDURES. DO NOT WEAR CONTAMINATED CLOTHING OR
    FOOTWEAR.
Supplemental Safety and Health
PER CHERON'S MSDS - A HAZARD WARNING IS NOT REQUIRED FOR THIS PRODUCT
    UNDER OSHA HAZARD COMMUNICATION STANDARD (29CFR 1910.1200)

==================  Physical/Chemical Properties  ==================

HCC:V6
Spec Gravity:0.88
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR, LIGHT BROWN LIQUID WITH RED BLOOM

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, SUCH AS CHLORATES, NITRATES,PEROXIDES.
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES
Hazardous Decomposition Products:INCOMPLETE COMBUSTION CAN PRODUCE
    CARBON MONOXIDE. NORMAL COMBUSTION FORMS CARBON DIOXIDE AND OXIDES
    OF SULFUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:PLACE CONTAMINATED MATERIALS IN DISPOSABLE
    CONTAINERS AND DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE
    FEDERAL, STATE AND LOCAL LAWS AND REGULATIONS. CONTACT LOCAL
    ENVIRONMENTAL OR HEALTH AUTHORITIES  FOR APPROVED DISPOSAL OF THIS
    MATERIAL.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.