DU PONT E I DE NEMOURS & CO INC -- FREON TF CLEANING AGENT FREON PRECISION CLEANING AGENT -- 6850-00-983-0282
=====================  Product Identification  =====================

Product ID:FREON TF CLEANING AGENT FREON PRECISION CLEANING AGENT
MSDS Date:10/19/1996
FSC:6850
NIIN:00-983-0282
MSDS Number: BGBLH
=== Responsible Party ===
Company Name:DU PONT E I DE NEMOURS & CO INC
Address:1007 MARKET STREET
Box:1635
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-7515/MSDS 302-992-3511
Emergency Phone Num:800-441-3637/800-424-9300(CHEMTREC)
Preparer's Name:ENGINE & PRODUCT SAFETY
CAGE:0BA38
=== Contractor Identification ===
Company Name:DU PONT E I  DE NEMOURS AND CO INC   PETROCHEMICALS DEPT
Address:1251 BRANDYWINE BLDG
Box:City:WILMINGTON
State:DE
ZIP:19898
Phone:302-773-5676
CAGE:73925
Company Name:DU PONT E I DE NEMOURS AND CO INC CHEM
Address:DELLE DONNE CORPORATE CTR
City:WILMINGTON
State:DE
ZIP:19880-0800
Country:US
Phone:800-441-7515
CAGE:0BA38

=============  Composition/Information on Ingredients  =============

Ingred Name:1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113) (SARA
    313)
CAS:76-13-1
RTECS #:KJ4000000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:1000PPM/1250STEL; 96
Ozone Depleting Chemical:1

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50: 43000MG/KG IN RATS.
Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:VERY LOW TOXICITY BY
    INHAL.LIFE-THREATENING EXPO MAY OCCUR IF HNDLD CARELESSLY.VAP
    HEAVIER THAN AIR POSING HAZ OF ASPHYXIATION IF TRAPPED IN
    ENCLSD/LOW PLACES.@FLAME TEMPS CMPD DECPO TO  HYDROGEN FLUO
    RIDE-LETHAL @LOW CONC.PRODUCT POSES HAZOF FATAL HEART IRREG IF
    INHAL @HI CONC.SKIN/EYE IRRIT.PROL SKIN (SIGNS/SYMPTOMS)
Explanation of Carcinogenicity:PER MSDS:NONE OF COMPONENTS PRESENT IN
    MATL @CONC =/> 0.1% ARE LISTED BY IARC/NTP/OSHA/ACGIH AS
    CARCINOGEN.
Effects of Overexposure:HEALTH HAZ:CONTACT DRYING.INHAL/INGEST CAUSE
    DIZZ,HEAD,CONFUSION,INCOORD,LOSS OF CONSC. MILD SKIN/EYE
    IRRIT,DISCOMFT,RASH,TINGLING NUMB,COLD,DRY.TEARING,BLUR
    VISION.ASPIRATION-CHEM PNEUMONIA,COUGH,GAS P,CHOKE,BREATH
    SHORTNESS,BLUISH DISCOLOR,RAPID
    BREATH,DROWS,CONF,COMA,SEIZURES.TEMP CNS DEPRESS,ALT HEART ELECT
    ACTIVITY
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHAL:IMMED REMOVE TO FRESH AIR.KEEP CALM.NOT BREATH GIVE ART
    RESP;DIFFI BREATH GIVE OXY.CALL DR.SKIN:FLUSH W/PLENTY OF WATER FOR
    15MINS.IRRIT PRESENT GET MED ATTN.EYE:IMMED FLUSH W/PLENTY OF WATER
    FO R 15MINS.CALL DR.INGEGST:NO SPECIFIC INTERVENTION INDICATED AS
    CMPD NOT LIKELY TO BE HAZ BY INGEST.DO NOT INDUCE VOMIT.HOWEVER
    CONSULT DR IF NECESSARY.DR:ADMIN ACTIVATE CHARCOAL
    SLURRY(50G/400ML)(SUP)

=====================  Fire Fighting Measures  =====================

Flash Point:WILL NOT BURN
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NP
Upper Limits:NP
Extinguishing Media:NONE SPECIFIED BY MANUFACTURER.
Fire Fighting Procedures:USE WATERSPRAY/FOG TO COOL
    CNTNR.SELF-CONTAINED BREATHING APPARATUS(SCBA)REQUIRED IF DRUMS
    RUPTURE & CONTENTS SPILLED UNDER FIRE CONDITIONS.
Unusual Fire/Explosion Hazard:DRUMS MAY RUPTURE UNDER FIRE CONDITIONS.
    DECOMPOSITION MAY OCCUR.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REVIEW MSDS.USE APPROPRIATE PPE DURING
    CLEANUP.VENTILATE AREA.DONT FLUSH INTO SEWERS.DIKE/COLLECT ON
    ABSORBENT MATL.TRANSF TO STEEL DR FOR RECOVER/DISPO.USE SCBA FOR LG
    SPILLS.COMPLY W/FED/STATE/LOC R EGS ON REPORTING RELEASES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID BREATH VAP/PROL SKIN EXPO.USE
    W/SUFFICIENT VENTI TO KEEP EMPLOYEE EXPO BELOW RECOMMENDED
    LIMITS.STORE IN CLEAN DRY AREA.DO NOT HEAT >125F.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:UNDER NORMAL USE CONDITIONS NO RESPIRATORY
    PROTECTION IS REQUIRED WHEN USING THIS PRODUCT.SELF-CONTAINED
    BREATHING APPARATUS IS REQUIRED IF LARGE SPILL OCCURS.
Ventilation:NORMAL VENTIL FOR STD USE PROCEDURES GEN ADEQUATE.LOC EXHAU
    FOR WHEN LG AMTS RELEASED.MECHAN VENTI IN LOW/ENCLSD PLACES.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEM SPLASH GOGG.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
1STAID:ADMIN 5ML/KG(350ML).CATECHOLAMINE DRUGS SHOULD BE USED W/SPECIAL
    CAUTION IN SITUATIONS OF EMERG LIFE SUPPORT.EMESIS/GASTRIC LAVAGE
    SHOULDN'T BE EMPLOYED UNLESS RISK IS JUSTIFIED BY PRESENCE OF  ADDN
    TOXIC SUBSTANCES.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:118F,48C
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:6.46PSIA
Vapor Density:2.9
Spec Gravity:DENS=1.57G/CC
pH:NEUTRA
Viscosity:NP
Evaporation Rate & Reference:>1 (CCL4=1).
Solubility in Water:0.02%, NEGLIGIBLE.
Appearance and Odor:SLIGHT ETHEREAL ODOR, LIQUID, CLEAR, COLORLESS.
Percent Volatiles by Volume:100
Corrosion Rate:NP

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE W/ALKALI OR ALKALINE EARTH METALS-POWDERED AL, ZN, BE,
    ETC.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:DECOMP PROD HAZ.CAN BE DECOMPO BY HI
    TEMP(OPN FLAME,GLOW METAL SURFACES,ETC)FORM HCL,HYDROFLUORIC
    ACIDS,CARBONYL HALIDES

====================  Disposal Considerations  ====================

Waste Disposal Methods:COMPLY W/FED/STATE/LOC REGS.REMOVE TO PERMITTED
    WASTE DISPO FACILITY.EPA HAZ WASTE #:F001,F002 MAY APPLY TO WASTE
    MATLS. CONTAINS TOXIC CHEM REQUIRED UNDER SEC 313 TITLE III
    SARA/40CFR372 TO BE REPORT ED.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.