UNION CARBIDE CORP., LINDE DIV. -- UCAR RUNWAY DEICER,PM-5197 -- 6850-00-237-4304
=====================  Product Identification  =====================

Product ID:UCAR RUNWAY DEICER,PM-5197
MSDS Date:09/21/1990
FSC:6850
NIIN:00-237-4304
MSDS Number: BDLZQ
=== Responsible Party ===
Company Name:UNION CARBIDE CORP., LINDE DIV.
Address:39 OLD RIDGEBURY RD
City:DANBURY
State:CT
ZIP:06817-0001
Country:US
Info Phone Num:304-744-3487
Emergency Phone Num:304-744-3487
CAGE:36346
=== Contractor Identification ===
Company Name:PHIPPS PRODUCTS CORP
Address:186 LINCOLN ST SUITE 502
Box:City:BOSTON
State:MA
ZIP:02111-2403
Country:US
Phone:OUT OF BUSINESS
CAGE:86511
Company Name:UNION CARBIDE CORP   LINDE DIV
Address:39 OLD RIDGEBURY RD
Box:City:DANBURY
State:CT
ZIP:06817-0001
Country:US
Phone:800-822-4357; 304-744-3487
CAGE:36346

=============  Composition/Information on Ingredients  =============

Ingred Name:ETHYLENE GLYCOL  (SARA III)
CAS:107-21-1
RTECS #:KW2975000
Fraction by Wt: 50%
OSHA PEL:C 50 PPM
ACGIH TLV:C 50 PPM,VAPOR; 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:UREA, 50% AQUEOUS
CAS:57-13-6
RTECS #:YR6250000
Fraction by Wt: 45%

Ingred Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 3.0%
Other REC Limits:NONE SPECIFIED

Ingred Name:DIPOTASSIUM HYDROGEN PHOSPHATE
CAS:16068-46-5
Fraction by Wt: 2.0%
Other REC Limits:NONE SPECIFIED

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGESTION:ABDOMINAL DISCOMFORT
    OR PAIN, NAUSEA, CENTRAL NERVOUS SYSTEM DEPRESSION. SEVERE KIDNEY
    AND LIVER DAMAGE FROM LARGE AMOUNTS; MAY BE FATAL.
    INHALATION:IRRITATION OF THE NOSE AND THROAT.  EYE:DISCOMFORT WITH
    TRANSIENT CONJUNCTIVITIS. CHRONIC: INHALATION OF MIST MAY PRODUCE
    SIGNS OF CNS DISTURBANCES.
Explanation of Carcinogenicity:NONE OF THE COMPOUNDS IN THIS PRODUCT IS
    LISTED BY IARC, NTP, OR OSHA AS A CARCINOGEN.
Effects of Overexposure:MAY CAUSE DIZZINESS, MALAISE, LUMBAR PAIN,
    OLIGURIA, UREMIA, AND CENTRAL NERVOUS SYSTEM DEPRESSION. MAY CAUSE
    EYE, SKIN & RESPIRATORY TRACT IRRITATION.
Medical Cond Aggravated by Exposure:THE AVAILABLE TOXICOLOGY
    INFORMATION AND A KNOWLEDGE OF THE PHYSICAL AND CHEMICAL PROPERTIES
    OF THE MATERIAL SUGGEST THAT OVEREXPOSURE IS UNLIKELY TO AGGRAVATE
    EXISTING MEDICAL CONDITIONS.

=======================  First Aid Measures  =======================

First Aid:INHALATION: REMOVE TO FRESH AIR. CALL A PHYSICIAN IF
    DISCOMFORT PERSISTS. EYE: IMMEDIATELY FLUSH EYES WITH PLENTY OF
    WATER FOR 15 MINUTES. CALL A PHYSICIAN. SKIN: WASH WITH PLENTY OF
    SOAP & WATER. REM OVE CONTAMINATED CLOTHING/SHOES. INGESTION: IF
    CONSCIOUS, GIVE 2 GLASSES OF WATER TO DRINK AND INDUCE VOMITING.
    GIVE NOTHING BY MOUTH IF UNCONSCIOUS. CALL A PHYSICIAN IMMEDIATELY.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
    CHEMICAL.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
    FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
    SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:NONE

==================  Accidental Release Measures  ==================

Spill Release Procedures:SMALL SPILL: WIPE/SOAK UP WITH PAPER TOWEL OR
    INERT ABSORBANT. PUT IN DISPOSAL CONTAINER. FLUSH RESIDUE WITH
    WATER. LARGE SPILL: VENTILATE AREA. IF POSSIBLE, STOP LEAK. DIKE TO
    RETAIN RUN OFF. VACUUM  UP FREE LIQUID. FLUSH RESIDUE WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. WATER DILUTION
    RECOMMENDED.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED
    AREA. KEEP CONTAINERS TIGHTLY CLOSED WHEN NOT IN USE. PROTECT
    CONTAINERS FROM PHYSICAL DAMAGE.
Other Precautions:DO NOT TAKE INTERNALLY. DO NOT BREATHE MIST. AVOID
    PROLONGED OR REPEATED BREATHING OF VAPOR. AVOID CONTACT WITH EYES.
    USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER HANDLING. FOR
    INDUSTRIAL USE  ONLY.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF VENTILATION DOES NOT MAINTAIN INHALATION
    EXPOSURES BELOW PEL(TLV), USE NIOSH/MSHA APPROVED ORGANIC VAPOR
    CARTRIDGE AND DUST/MIST PRE-FILTER RESPIRATORS AS PER CURRENT 29
    CFR 1910.134, INSTRUCTIONS/ WARNINGS AND NIOSH-RESPIRATOR
    SELECTION.
Ventilation:MECHANICAL (GENERAL) ROOM VENTILATION IS ADEQUATE IF USE IS
    ENCLOSED. LOCAL EXHAUST IS NEEDED IF VENTED INTO WORK AREA.
Protective Gloves:NEOPRENE, NITRILE, PVC OR NATURAL RUBBER
Eye Protection:SAFETY GOGGLES WITH OPTIONAL FACE SHIELD
Other Protective Equipment:EYE WASH STATION AND SAFETY SHOWER.
    INDUSTRIAL-TYPE WORK CLOTHING AND APRON AS REQUIRED.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
    RECOMMENDED PROCEDURES. DO NOT WEAR CONTAMINATED CLOTHING OR
    FOOTWEAR.
Supplemental Safety and Health
DO NOT TAKE INTERNALLY. DO NOT GET ON SKIN OR IN EYES. AVOID PROLONGED
    OR REPEATED BREATHING OF VAPOR. DO NOT BREATHE MISTS. WASH
    THOROUGHLY AFTER HANDLING AND BEFORE EATING OR DRINKING OR SMOKING
    OR	USING RESTROOM.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:241F/116C
Vapor Pres:9.3
Vapor Density:@ 2.1
Spec Gravity:1.149
Evaporation Rate & Reference:0.8 (BUTYL ACETATE=1)
Solubility in Water:100
Appearance and Odor:BLUE LIQUID,MILD AMMONIACAL ODOR

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS AND BASES AND SUBJECTED TO ELEVATED TEMPS.. STRONG
    OXIDIZING AGENTS; HYDROXYL COMPOUND REACTIVE MATERIALS.
Stability Condition to Avoid:HIGH TEMPERATURES
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE AND
    OXIDES OF NITROGEN.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL SHOULD BE MADE BY INCINERATION IN
    ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS AND
    REGULATIONS. AT VERY LOW CONCENTRATIONS IN WATER, DISPOSE OF THIS
    MATERIAL IN A BIOLOGICAL W ASTEWATER TREATMENT PLANT.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.