E.I. DUPONT DE NEMOURS & CO. -- FREON 113 -- 6830-00-144-4957
=====================  Product Identification  =====================

Product ID:FREON 113
MSDS Date:01/01/1985
FSC:6830
NIIN:00-144-4957
MSDS Number: BDBYP
=== Responsible Party ===
Company Name:E.I. DUPONT DE NEMOURS & CO.
Emergency Phone Num:302-774-2421
CAGE:19898
=== Contractor Identification ===
Company Name:E.I. DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515;800-441-9442
CAGE:18873
Company Name:E.I. DUPONT DE NEMOURS & CO., INC.
Box:1635
CAGE:19898

=============  Composition/Information on Ingredients  =============

Ingred Name:1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113)  (SARA
    III)
CAS:76-13-1
RTECS #:KJ4000000
Fraction by Wt: 100%
OSHA PEL:1000PPM/1250STEL
ACGIH TLV:1000PPM/1250STEL9192
Ozone Depleting Chemical:1

=====================  Hazards Identification  =====================

Effects of Overexposure:LIGHT-HEADINESS, GIDDINESS, SHORTNESS OF BRTH,
    POSS NARCOSIS & CARDIAC ARRHYTHMIAS AT HIGH CONC.

=======================  First Aid Measures  =======================

First Aid:INH: REMOVE TO FRESH AIR, CALL MD.  DO NOT GIVE EPINEPHRINE
    OR SIMILAR DRUGS.  SKIN/EYE: FLUSH WITH WATER

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:NONFLAMMABLE
Fire Fighting Procedures:SELF-CONTAINED BRTHNG APPAR FOR VAPORS & FUMES
Unusual Fire/Explosion Hazard:NONE

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILAE AREA - ESPECIALLY LOW PLACES WHERE
    HEAVY VAPORS MIGHT COLLECT.  REMOVE OPEN FLAMES AND OTHER IGNIT
    SOURCES. FOR LG SPILLS THOSE CLEANING UP MAY REQUIRE APPRVD
    SELF-CONTAINED BRTHNG APPAR.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE CONTAINERS IN A CLEAN, DRY AREA.
    DO NOT HEAT ABOVE 125F.  KEEP IN WELL VENTILATED PLACE.  NO SMOKING
    IN AREAS OF USE.
Other Precautions:VAPORIZATION OF EXCESS AMTS OF PROD CAN
    DEPLETE/REPLACE O*2 NEC FOR BREATH. IN CONFINED/ENCLOSED SPACES OR
    W/LITTLE VENT THIS MAY BE HEALTH HAZ. HIGH CONC MAY INDUCE CARDIAC
    ARRHYTHMIAS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED AIR MASKS IN HIGH CONC.
Ventilation:SUFFICIENT WHEN LG AMOUNTS ARE RELEASED, ESP IN LOW AREAS
Protective Gloves:YES
Eye Protection:YES
Other Protective Equipment:PROVIDE EYEWASH STATIONS WHERE SPLASHING IS
    POSSIBLE.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:T6
Boiling Pt:B.P. Text:117.6F
Vapor Pres:334
Vapor Density:2.9
Spec Gravity:1.57
Evaporation Rate & Reference:0.3(CCL*4)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS LIQUID,SLIGHT ETHEREAL ODOR
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS - POWDERED AL, ZN, BE, ETC.
Stability Condition to Avoid:OPEN FLAMES OR HIGH TEMPERATURES.
Hazardous Decomposition Products:HYDROCHLORIC & HYDROFLUORIC ACIDS -
    POSS PHOSGENE

====================  Disposal Considerations  ====================

Waste Disposal Methods:MFR RECM EVAPORATE OUTDOORS.  DISPOSE LAW, FED,
    STATE & LOCAL CODES

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.