DOW CHEMICAL U.S.A. -- D.E.R. 332,EPOXY RESIN -- 8040-00-023-7722
=====================  Product Identification  =====================

Product ID:D.E.R. 332,EPOXY RESIN
MSDS Date:01/01/1985
FSC:8040
NIIN:00-023-7722
MSDS Number: BCVND
=== Responsible Party ===
Company Name:DOW CHEMICAL U.S.A.
Emergency Phone Num:517636-4400
CAGE:96717
=== Contractor Identification ===
Company Name:DOW CHEMICAL CO
Address:100 LARKIN CENTER
Box:City:MIDLAND
State:MI
ZIP:48674
Country:US
Phone:800-258-2436
CAGE:96717

=============  Composition/Information on Ingredients  =============

Ingred Name:BISPHENOL A & EPICHLOROHYDRIN;REACTION PRODUCTS OF
Fraction by Wt: 100%

Ingred Name:SUPDAT: (DGEBPA)-BASED EPOXY RESINS. IN ONE OF THESE
    DGEBPA-BASED RESIN (CNTNG HIGH LEVELS OF SEVERAL IMPURITIES (ING 3)
RTECS #:9999999ZZ

Ingred Name:ING 2: (INCL KNOWN ANIMAL SKIN CARCIN) WAS REPORTED TO
    PRDCE WEAK CARCIN RESPONSE IN SKIN OF 1 OF 2 STRAINS OF (ING 4)
RTECS #:9999999ZZ

Ingred Name:ING 3:MICE TESTED. RECENT STUDIES HAVE SUGGESTED SLIGHT
    INCRS IN 2 SYSTEMIC TUMOR TYPES FOLLOWING RPTD APPLICATN (ING 5)
RTECS #:9999999ZZ

Ingred Name:ING 4: OF CERTAIN DGEBPA-CNTNG RESINS (OR PURE DGEBPA),
    ALTHOUGH RESPONSE WAS NOT UNIFORM AMONG PRACTICALLY (ING 6)
RTECS #:9999999ZZ

Ingred Name:ING 5:IDENTICAL RESINS. BASED ON DATA & OTHER STUDIES NOT
    SHOWING CANCER, CAUSE-EFT RELATIONSHIP BETWEEN DGEBPA- (ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6: TREATMENT & TUMOR INCRS IS QUESTIONABLE. IARC
    CONCLUDES DGEBPA IS NOT CLASSIFIABLE AS TO CARCINOGENICITY. (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7: IN VITRO MUTAGENICITY STUDIES WERE NEGATIVE IN SOME
    CASES & POSITIVE IN OTHERS.
RTECS #:9999999ZZ

Ingred Name:SPILL PROC: POLYPROPYLENE/POLYETHYLENE FIBER PRODS &
    COLLECT IN SUITABLE CNTNRS. RESIDUAL RESIN MAY BE REMOVED (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9: USING STEAM OR HOT SOAPY H*2O. METHYLENE
    CHLORIDE/OTHER SOLVS IN CLEANUP POSES DISTINCT HAZ & SHOULD BE
    AVOIDED.
RTECS #:9999999ZZ

Ingred Name:WASTE DISP:STOR, OTHERWISE ALTERING MATL MAY MAKE WASTE
    MANAGEMENT INFO IN MSDS INCOMPLETE/INACCURATE/OTHERWISE (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11:INAPPROP. WASTE CHARACTERIZATION & DISP COMPLIANCE
    ARE RESPONSIBILITY SOLELY OF PARTY GENERATING WASTE (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12: OR DECIDING TO DISCARD/DISPOSE OF MATL. NONE OF
    THESE WASTE MANAGEMENT OPTIONS SHOULD BE CONSIDERED (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13: 'ARRANGING FOR DISP.' DO NOT ALLOW INTO ANY SEWERS,
    ON GROUND OR INTO ANY BODY OF WATER. PREF WASTE (ING 15)
RTECS #:9999999ZZ

Ingred Name:ING 14: MANAGEMENT OPTION FOR UNUSED, UNCONTAMD,
    UNFORMULATED OR NOT OTHERWISE ALTERED MATL IS TO SEND TO (ING 16)
RTECS #:9999999ZZ

Ingred Name:ING 15:PROPERLY LICENSED OR PERMITTED RECYCLER, RECLAIMER
    OR INCINERATOR. SAME WASTE MANAGEMENT OPTIONS ARE REC (ING 17)
RTECS #:9999999ZZ

Ingred Name:ING 16:FOR USED/CONTAMD MATL, ALTHOUGH ADDNL EVALUATION IS
    REQD. REFER TO 40 CFR 261 &/OR ANY OTHER APPROP FED, (ING 18)
RTECS #:9999999ZZ

Ingred Name:ING 17:STATE, PROVINCIAL OR LOC REQS FOR PROPER
    CLASSIFICATION. FOR ADDNL INFO SEE MSDS REACTIVITY OR
    REGULATORY(ING 19)
RTECS #:9999999ZZ

Ingred Name:ING 18:INFO. AS SERVICE TO ITS CUSTOMERS, MFR CAN PROVIDE
    LISTS OF COMPANIES WHICH RECYCLE, REPROCESS OR MANAGE (ING 20)
RTECS #:9999999ZZ

Ingred Name:ING 19:CHEMS AS WELL AS LISTS OF COMPANIES THAT RECONDITION
    USED DRUMS. CALL 517-832-1556 OR 800-258-2436 FOR MORE INFO.
RTECS #:9999999ZZ

Ingred Name:OTHER PROT EQUIP: SUCH AS FSHLD, GOLVES, BOOTS, APRON OR
    FULL-BODY SUIT WILL DEPEND ON OPERATION.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LDS0 SKIN ABSORB IS 20000 MG/RG RABBITS.
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Explanation of Carcinogenicity:IARC:PROBABLE HUMAN CARCINOGENS (GROUP
    2B).NTP:ANTICIPATED TO BE CARC.
Effects of Overexposure:NO HAZ ANTICIPATED FROM INGESTION INCIDENTAL TO
    IND EXPOS.

=======================  First Aid Measures  =======================

First Aid:EYES:IRRIGATE W/ COPIOUS AMOUNTS OF H*2O FOR ATLEAST 15
    MINUTES..

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:485 F- 252 C
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL
Fire Fighting Procedures:WEAR POSITIVE PRESSURE SCBA.
Unusual Fire/Explosion Hazard:NONE

==================  Accidental Release Measures  ==================

Spill Release Procedures:SOAK UP IN ABSORBENT MAT SUCH AS SAND +
    COLLECT IN SUITABLE CONTAINERS.RESIDUAL RESIN REMOVE W/ STEAM/HOT
    SOAPY H*2O.METHYLENE CHLORIDE,OTHER SOLVENTS IN CLEANUP POSES HAZ.+
    SHOULD BE AVOIDED.KEEP SPA RKING EQUIP AWAY LG SPILL CONTAIN W/
    DIKE.

======================	Handling and Storage  ======================

Handling and Storage Precautions:PRACTICE GOOD CAUTION AND PERSONAL
    CLEANLINESS TO AVOID SKIN AND EYE CONTACT.AVOID BREATHING VAPORS OF
    HEATED MATERIAL
Other Precautions:MFG SUGGESTS INFORMATION FROM THE DOW
    BULLETIN:"STORAGE & HANDLING OF DOW EPOXY RESINS"

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE LIKELY NEEDED
Ventilation:ADEQUATE
Protective Gloves:IMPERVIOUS
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:CLEAN,BODY COVERING CLOTHING.DISPOSABLE
    CONTAINERS & PAPER
Supplemental Safety and Health
LD50 FOR RATS IS 74000 MG/KG.COND AVOID POLYMERIZATION:POLYMERIZATION
    W/ CONSTDERABLE HEAT BUILD-UP.

==================  Physical/Chemical Properties  ==================

HCC:N1
NRC/State Lic Num:NA
Spec Gravity:1.160
Solubility in Water:NONE
Appearance and Odor:LIQUID TO SEMI-SOLID-WATER WHITE TO LIGHT YELLOW

=================  Stability and Reactivity Data  =================

BASES
Stability Condition to Avoid:EXCESS HEATING OVER LONG PERIOD DEGRADES
    THE RESIN
Conditions to Avoid Polymerization:WILL NOT OCCURE BY ITSELF,MASSES OF
    MORE THAN 1 LB OF PRODUCT + ALIPHATIC AMINE WILL CAUSE IRREVERSIBLE
    (SEE SUP DATA)

====================  Disposal Considerations  ====================

Waste Disposal Methods:BURY IN LANDFILL OR USE INCINERATOR IF IN
    ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.